Standard: IEC 61215
Order No.: Client: Changzhou Kinder Industry Co., Ltd.
Product: PV modules Max. system voltage 1000V DC
Project Engineer: Voc (V) See attached table in P3
Test Engineer: Isc (A) See attached table in P3
Application Date: Vmp (V) See attached table in P3
Requested Date: Imp (A) See attached table in P3
Re-test: 0
Pmp (W) See attached table in P3
Full-test: 1
Number of cells See attached table in P3
Other information:
Result Clause(s) Test(s) Page
0F 0P
10.1 Visual inspection
0F 0P
10.2 Maximum power determination
0F 0P
10.3 Insulation test
0F 0P
10.4 Measurement of temperature
0F 0P
10.5 Measurement of NOCT
0F 0P
10.6 Performance at STC and NOCT
0F 0P
10.7 Performance at low irradiance
0F 0P
10.8 Outdoor exposure test
0F 0P
10.9 Hot-spot endurance test
0F 0P
10.1 UV preconditioning
0F 0P
10.11 Thermal cycling test
0F 0P
10.12 Humidity freeze test
0F 0P
10.13 Damp heat test
0F 0P
10.14 Robustness of termination test
0F 0P
10.15 Wet leakage current test
0F 0P
10.16 Mechanical load test
0F 0P
10.17 Hail test
0F 0P
10.18 Bypass diode thermal test
Remark :
If IEC 61730 is applied with IEC 61215,Tests of MST 01, MST 16, MST 13 and MST 11 shall be performed before the preconditioning test in IEC 61215 and test results shall be filled in the test datasheet of IEC 61730-2
Total page : 54pages
....................................... .......................................
Date Signature Date Signature
Record by Test Engineer Check by Project Engineer
Product Electrical Rating
Model KD-200W KD-220W KD-230W KD-240W KD-250W KD-260W KD-270W KD-280W
Voc (V) 33.2 42.2 37 43.2 43.4 43.6 43.8 44.2
Isc (A) 7.72 7.48 8.38 7.7 7.8 7.9 8.1 8.3
Vmp (V) 26.6 34 30 34.4 34.6 34.8 35.2 35.2
Imp (A) 7.52 6.47 7.66 6.98 7.23 7.47 7.67 7.95
Pmp (W) 200 220 230 240 250 260 270 280
Number of cells 54 60 72 72 72 72 72 72
Series fuse rating(A)
identification
Sample Number Serial number
1
2
3*
4*
5
6
7
8
Comments:
* The small dimension samples
clause 5) Preconditioning ( all samples ) Remarks
All modules (including control) shall be exposed to sunlight (real or simulated)to an irradiation level of 5 KWh/m2 to 5.5 KWh/m2
0 Done
Clause 10.1 Visual Detection (sample 1 )
Remarks
Inspect each module according to the relevant working instruction
Kind of defect Defect present
Cracked, bent, misaligned or torn external surfaces 0 Yes 0 No
broken cells 0 Yes 0 No
cracked cells 0 Yes 0 No
faulty interconnections on joints 0 Yes 0 No
cells touching one another or the Frame 0 Yes 0 No
failure of adhesive bonds 0 Yes 0 No
bubbles or delamination forming a continuous path between the cell and the edge of the module 0 Yes 0 No
tacky surfaces of plastic materials 0 Yes 0 No
faulty terminations, exposed live electrical parts 0 Yes 0 No
any other conditions which may affect the performance 0 Yes 0 No
Comments:
Clause 10.1 Visual Detection (sample 2 )
Remarks
Inspect each module according to the relevant working instruction
Kind of defect Defect present
Cracked, bent, misaligned or torn external surfaces 0 Yes 0 No
broken cells 0 Yes 0 No
cracked cells 0 Yes 0 No
faulty interconnections on joints 0 Yes 0 No
cells touching one another or the Frame 0 Yes 0 No
failure of adhesive bonds 0 Yes 0 No
bubbles or delamination forming a continuous path between the cell and the edge of the module 0 Yes 0 No
tacky surfaces of plastic materials 0 Yes 0 No
faulty terminations, exposed live electrical parts 0 Yes 0 No
any other conditions which may affect the performance 0 Yes 0 No
Comments:
Clause 10.1 Visual Detection (sample 3 )
Remarks
Inspect each module according to the relevant working instruction
Kind of defect Defect present
Cracked, bent, misaligned or torn external surfaces 0 Yes 0 No
broken cells 0 Yes 0 No
cracked cells 0 Yes 0 No
faulty interconnections on joints 0 Yes 0 No
cells touching one another or the Frame 0 Yes 0 No
failure of adhesive bonds 0 Yes 0 No
bubbles or delamination forming a continuous path between the cell and the edge of the module 0 Yes 0 No
tacky surfaces of plastic materials 0 Yes 0 No
faulty terminations, exposed live electrical parts 0 Yes 0 No
any other conditions which may affect the performance 0 Yes 0 No
Comments:
Clause 10.1 Visual Detection (sample 4 )
Remarks
Inspect each module according to the relevant working instruction
Kind of defect Defect present
Cracked, bent, misaligned or torn external surfaces 0 Yes 0 No
broken cells 0 Yes 0 No
cracked cells 0 Yes 0 No
faulty interconnections on joints 0 Yes 0 No
cells touching one another or the Frame 0 Yes 0 No
failure of adhesive bonds 0 Yes 0 No
bubbles or delamination forming a continuous path between the cell and the edge of the module 0 Yes 0 No
tacky surfaces of plastic materials 0 Yes 0 No
faulty terminations, exposed live electrical parts 0 Yes 0 No
any other conditions which may affect the performance 0 Yes 0 No
Comments:
Clause 10.1 Visual Detection (sample 5 )
Remarks
Inspect each module according to the relevant working instruction
Kind of defect Defect present
Cracked, bent, misaligned or torn external surfaces 0 Yes 0 No
broken cells 0 Yes 0 No
cracked cells 0 Yes 0 No
faulty interconnections on joints 0 Yes 0 No
cells touching one another or the Frame 0 Yes 0 No
failure of adhesive bonds 0 Yes 0 No
bubbles or delamination forming a continuous path between the cell and the edge of the module 0 Yes 0 No
tacky surfaces of plastic materials 0 Yes 0 No
faulty terminations, exposed live electrical parts 0 Yes 0 No
any other conditions which may affect the performance 0 Yes 0 No
Comments:
---------------------------------------------------------------我们可以专业周到提供真正一站式服务,彻底解决您的后顾之忧。我们信念:坚持真诚服务、做百年服务企业!与客户共发展,共赢未来!欢迎来电咨询我们:(来电即有优惠!)深圳分中心电话:0755-82339470东莞分中心电话:0769-83666658网址:www.cert-service.orgQQ:1823728544